Fluorine lined gate valve

Design&Manufacture Standard
GB/T12234 API 6D
Normal Diameter
DN15~DN350 1/2”~14”
Normal Pressure
1.0MPa 1.6MPa 150LB
Temperature Range
FEP:-29℃~120℃, PFA:-29℃~180℃, PTFE:-29℃~150℃
Applicable Medium
Strong corrosion medium: Hydrochloric acid, Nitric acid, Hydrofluoric acid, Liquid chlorine, Sulfuric acid and Aqua regia etc.
Body Material
WCB CF8 CF3 CF8M CF3M
GET A QUOTE
Do you have a question?
PARAMETER
ADVANTAGE

A fluorine-lined gate valve controls the flow of corrosive fluids in industries like chemical processing and water treatment. The internal surfaces are coated with a fluorine lining, providing resistance to chemical corrosion.

The valve operates by raising or lowering a gate to start or stop fluid flow. When fully open, it allows fluid to pass through with minimal pressure drop. This design is suitable for on-off applications, ensuring the medium is isolated without contact with internal components.

Main parts and materials

Name/MaterialWCBCF8CF3CF8MCF3M
BodyWCBCF8CF3CF8MCF3M
StemWCBCF8CF3CF8MCF3M
PlugWCBCF8CF3CF8MCF3M
LinedFEP / PFA / PO / PTFE
SeatPTFE / RPTFE
Bolt/NutB7/2HB8/8B8/8B8M/8MB8M/8M

Technical Specification

Design&Manufacture StandardGB/T12234API 6D
FTF Dimension StandardHG/T3704, GB/T12221ASME B16.10
Flange standardHG/T20592, GB/T9119ASME B16.5, JIS B2220
Inspection & Test StandardHG/T13927, JB/T9092API 598
Normal DiameterDN15~DN350 1/2”~14”
Normal Pressure1.0MPa1.6MPa150LB
Test pressureShell Test1.5MPa1.5MPa1.5MPa
High Pressure Test1.1MPa1.1MPa1.1MPa
Low Pressure Test0.6MPa0.6MPa0.6MPa
Temperature RangeFEP:-29℃~120℃, PFA:-29℃~180℃, PTFE:-29℃~150℃
Applicable MediumStrong corrosion medium: Hydrochloric acid, Nitric acid, Hydrofluoric acid, Liquid chlorine, Sulfuric acid and Aqua regia etc.

The main connection size

DN (mmPNS (Inch)LDD1D2fbZ-ΦdH
25116011585653174-14230
321-1/4180140100753194-18245
401-1/2240150110853194-18285
5022501651251003214-18300
652-1/22701851451203214-18340
8032802001601353218-18410
10043002201801553238-18465
12553252502101854248-18620
15063502852402104268-23710
20084003402952654268/12-23780
2501045039535032042812-23/261000

Fluorine-lined gate valve is a kind of valve. The opening and closing part of the fluorine-lined gate valve is the gate plate. The direction of movement of the gate plate is perpendicular to the direction of the fluid. The gate valve can only be fully opened and fully closed, not adjusted and throttled. The gate has two sealing surfaces. The most commonly used mode is that the two sealing surfaces of the gate valve form a wedge shape. The wedge angle varies with the valve parameters.

Excellent Corrosion Resistance:

The fluorine lining protects the valve from corrosive chemicals, making it suitable for harsh environments and aggressive fluids.

Extended Service Life:

The lining enhances the durability of the valve, reducing wear and increasing longevity, even in challenging applications.

Wide Temperature Tolerance:

Fluorine-lined gate valves perform well in a range of temperatures, ensuring reliable operation in both high and low-temperature environments.

Prevention of Fluid Contamination:

The fluorine lining prevents the fluid from reacting with the valve body, ensuring purity in sensitive processes.

Low Operating Torque:

The smooth internal lining reduces friction, allowing for easier operation and reduced wear on the valve components over time.

PRODUCT VIDEO
Stop Stop
LOOKING FOR A FIRST-CLASS SCIENTIFIC PARTNER?
Contact Lianke +
OTHER PINCH VALVAS
Weir type rubber lined diaphragm valve

A weir-type diaphragm valve is a specific design of diaphragm valve that features a raised lip or saddle in the valve body. The diaphragm comes into contact with this weir to form a seal and control fluid flow. Main parts and materials Name/Material CI WCB CF8 CF3 CF8M CF3M Body CI WCB CF8 CF3 CF8M CF3M Diaphragm […]

Straight through type rubber lined diaphragm valve

A straight-through diaphragm valve controls fluid flow in a pipeline using a diaphragm that moves vertically to open or close the flow path. The straight-through design allows fluid to pass directly through the valve, reducing pressure drop and maintaining efficient flow. It is commonly used in applications where reliable sealing and minimal obstruction are needed, […]

Fluorine lined plug valve

A plug valve controls fluid flow in a pipeline using a cylindrical or tapered plug with a central hole. The plug rotates within the valve body to open or close the flow path. When the plug aligns with the pipeline, fluid passes through. When turned so the hole is perpendicular to the flow, it blocks […]

Fluorine lined control valve

A fluorine lined control valve regulates the flow of fluids in a pipeline, adjusting flow rate, pressure, and temperature. It works by changing the size of the flow passage using elements like plugs, balls, or diaphragms. Control valves are crucial in industrial processes for maintaining operating conditions and ensuring system efficiency. They can be operated […]

FOR FURTHER INFORMATION
CONTACT US
Contact Lianke +